Special Feature:  
 
 BACK
 
 
Seat sealing:
At the high line pressure,the sealing force pushes the seat against ball to create a tight seal.
At the low line pressure,the tight seal is provided by spring force against ball.
 

Seating force=line pressure(p1)¡Á(A1-A2)
 
  -----------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
 
Low Fricition Bearing:
The self lubricated PTFE coated bearings in the stem,gland and trunnion area maintain the valve for low operating torque and provide a long service life.
Top Entry Construction:
Top Entry Trunnion Ball Valve offers inline service of the stem ball,seats and springs. Removal of the gland provides easy access for- maintenance and service.
¡¡
  Fire-safe Feature:          
 
Should the soft seats be destroyed by fire,the fluid/seat springs pressure push the metal seating to the ball,thus providing a secondary tight metal seal as a fire safe mechanism.
Fire-Safe gasket is provided to back-up the primary O-rings seals.
¡¡  
  Security Feature          
 
Optional Locking Device:
DHV lever and operated ball valves are available with an optional locking device in either the full open or closed position to protect against unauthorized operation.
   
 
  ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
 
Cavity Relief:
When cavity pressure increases within the ball valve body,automatic pressure relief will occur by relieving the body cavity pressure past the downstream seat.
Anti Static Device
The springs between the ball and stem provide anti-static continuity through-out all valve parts.
  ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
 
Sealant injection Fitting:
DHV valve is supplied with a standard stem sealant injection fitting.Seat sealant fittings backup by a internal check valve are also standard on DHV valve are also standard on DHV valve 6" and larger.In the event a seat should be damaged,the sealant could be injected through seat injection fitting to provide an emergency shutoff.
 
 
  Design Torque for Actuator Sizing (ft-lbs)

 
 
Side Entry Trunnion Ball Valve
Class/Working Pressure(psi)
2"FP
3"RP
3"FP
4"RP
4"FP
6"RP
6"FP
8"RP
8"FP
10"RP
10"FP
12"RP
150/285
41
41
107
107
173
173
258
258
502
502
900
900
300/740
55
55
145
145
203
203
391
391
886
886
1351
1351
600/1480
92
92
210
210
365
365
701
701
1343
1343
2402
2402
900/2220
166
166
341
341
576
576
1100
1100
2103
2103
3432
3432
1500/3705
181
181
406
406
775
775
1845
1845
3358
3358
6089
6089
2500
351
351
649
649
1007
1007
3926
3926
6310
6310
8856
8856
Class/Working Pressure(psi)
12"FP
14"RP
14"FP
16"RP
16"FP
18"RP
18"FP
20"RP
20"RP
22"FP
22"FP
24"FP
150/285
1190
1190
1734
1734
2177
2177
2620
2620
3653
4871
4200
4200
300/740
1860
1860
2472
2472
3506
3506
4598
4598
6362
7601
6973
6973
600/1480
3210
3210
4565
4565
6089
6089
8576
8576
11476
15277
18280
18280
900/2220
5351
5351
7616
7616
9963
9963
12620
12620
16974
21033
31293
31293
1500/3705
9963
9963
12915
12915
17343
17343
23837
23837
30627
38007
2500
11070
11070
24500
24500
N/A
N/A
N/A
N/A
N/A
N/A
Class/Working Pressure(psi)
24"FP
26"RP
26"FP
28"RP
28"FP
30"RP
30"FP
32RP
32"FP
36"RP
36"FP
150/285
5793
5553
7011
6412
9594
7252
8240
8240
9215
9215
12494
300/740
9793
9557
11830
10616
14317
11521
13795
13795
15511
15511
21030
600/1480
18155
23031
20590
29438
23948
34233
38790
38790
44000
44000
53302
900/2220
25092
39211
29040
33210
1500
42509
46464
55350

Top Entry Trunnion Ball Valve
Class/Working Pressure(psi)
1/-1/2"FF
2"RP
2"FP
3"RP
3"FP
4"RP
4"FP
6"RP
6"FP
8"RP
150/285
32.5
32.5
35.5
35.5
75.4
75.4
166
166
208
208
300/740
55.4
55.4
62
62
130.5
130.5
289
289
412
412
600/1480
64
64
70.4
70.4
148
148
329
329
692
692
900/2220
85
85
96
96
187
187
423
423
938
938
1500/3705
126
126
146
146
266
266
610
610
1430
1430
Class/Working Pressure(psi)
8"FP
10"RP
10"FP
12"RP
12"FP
 14" RP
 14" FP
 16" RP
16" FP
18" RP
150/285
454
454
828
828
1035
 1035
1307 
1307 
1739
1739
300/740
680
680
1300
1300
1890
1890
2501 
2501 
3470
3470
600/1480
1182
1182
2316
2316
3389
3389
4522 
4522 
5550
5550
900/2220
2000
2000
3099
3099
4459
4459 
6167 
6167 
7316
7316
1500/3705
3667
3667
4664
4664
6598
6598 
8334 
8334 
9925
9925
Additional sizing information available upon request.
Consult factory safety factor.

Flow Coefficient (Cv) Value for DHV Trunnion Ball Valves

Valve Size
Class
2"x1-1/2"
2"
3"x2"
3"
4"¡x3"
4"
6"x4"
6"
8"x6"
8"
150LB
140
511
220
1380
630
2580
799
5450
1760
10660
300LB
140
567
210
1167
600
2235
762
5400
1760
10660
600LB
108
406
195
1043
475
1890
740
4580
1750
8900
900LB
106
362
193
1005
470
1825
730
4380
1740
8420
1500LB
106
362
191
907
470
1670
730
4080
1730
7930
Class
10"x8"
10"
12"x10"
12"
14"¡x12"
16"¡x12"
14"
16"
18"¡x16"
18"
150LB
4200
17720
7400
26600
14000
9000
36700
44500
21000
56650
300LB
4150
17170
7350
25700
13950
8950
31500
42000
20800
52350
600LB
4100
14600
7300
22600
13900
8900
900LB
4050
14140
7250
21100
13850
8850
1500LB
3800
13040
7000
19500
13600
8600